    • Resmed S9 Autoset

      Designed to maximise comfort, the S9 AutoSet™ automatically delivers the ideal combination of Automatic Positive Airway Pressure (APAP) with Easy-Breathe™ Expiratory Pressure Relief (EPR) to prevent the collapse of your upper airway during sleep.

      The newly enhanced, intelligent algorithm built into ResMed’s sleep therapy system delivers more effective, accurate therapy for maximum comfort. This special algorithm maintains the ideal air pressure – automatically adjusting through the night to deliver the optimal therapy.

      With the S9 AutoSet you enjoy peace of mind because you know the right therapy is always delivered. We call it AutoSet, you’ll call it brilliant.

      The new S9 AutoSet was designed with patient comfort and compliance in mind whilst also providing the sleep professional the necessary technical innovation and therapy insight to ensure efficient patient management and clinical success. Building on the success of its predecessors, the S9 AutoSet now combines an enhanced AutoSet Advantage™ with the core platform benefits of the S9 series to create a truly unique APAP standard and more comfortable therapy experience.

      The Enhanced AutoSet Advantage The AutoSet Advantage has evolved. As before, the AutoSet responds to flow limitation, snore and obstructive apneas to deliver optimal pressures night after night. But now, the enhanced Auto- Set provides an additional response to open events via an event responsive Forced Oscillation Technique (FOT) which responds to obstructive and open airway events differently

      New AutoSet Features
      • Enhanced AutoSet Advantage The enhanced AutoSet algorithm with central and obstructive event detection, response and scoring via an event responsive FOT
      • Easy-Breathe Technology Easy-Breathe motor technology for unrivalled radiated and conducted noise levels
      • Easy-Breathe EPR The option of Easy-Breathe EPR in both AutoSet and fixed CPAP modes
      • Ramp Ramp in AutoSet and CPAP modes
      • Optional Climate Control o Absolute humidity delivery regardless of changes to ambient conditions or therapy pressure throughout the night o Temperature control for greater patient comfort
      • Compatibility Algorithm compatibility with H5i humidifier, 15mm SlimLine and ClimateLine tubing plus 19mm standard tubing

      Therapy Insight
      • Summary Data Summary, efficacy and usage data for up to 365 nights including central apnea statistics
      • Detailed Data Detailed efficacy and usage data for up to 30 nights
      • Additional parameters 30 nights’ data on additional parameters including flattening index, snore, minute ventilation and oximetry (when oximeter is connected)
      • Flow data High-resolution flow data at 25Hz for up to 7 nights.
      • Sleep Quality Indicator

      Operating pressure range 4 to 20 cm H2O
      Sound pressure level
      24 dBA with uncertainty of 2 dBA as measured according to
      ISO 17510-1:2002
      Dimensions (L x W x H) 153 x 140 x 86mm
      Weight 810g
      90W power supply unit
      Input range 100-240V, 50-60Hz, 70VA (typical power consumption), >100VA (maximum power consumption)
      Operating:
      temperature +5°C to +35°C
      humidity 10-95%, non-condensing
      altitude Sea level to 2,591 m
      Storage and transport:
      temperature -20°C to +60°C
      humidity 10-95% non-condensing
      Housing construction
      Flame retardant engineering thermoplastic
      Supplemental oxygen
      Recommended maximum supplemental oxygen flow: 4L/min
      Standard air filter Polyester fibre
      SlimLine™ air tubing
      Flexible plastic, 1.83m, 15mm inner diameter
      Air outlet
      The 22mm conical air outlet complies with ISO 5356-1
      electromagnetic Compatibility
      requirements (EMC) according to IEO60601-12. For residential,
      commercial, and light industry environments.
      Aircraft use
      These S9 devices comply with US FFC Part 15, Class B
      requirements if no external data cables are used.
      IEC 60601-1 classification
      Class II (double insulation), Type BF

      H5i - Humidification and Climate Control

      Climate Control
      Explaining to a patient why humidification is important and configuring a humidifier can be challenging. These issues are resolved when providing the S9, H5i and ClimateLine tubing as a combination known as Climate Control. For the first time, air is delivered at the temperature your patients demand whilst five sensors, including one close to the mask, monitor multiple conditions to provide optimal humidification – automatically. In addition, rainout – which causes “gurgling” noises, variable pressure swings and water condensation on the face, are effectively managed with Climate Control when in Auto mode. To set up Climate Control connect the ClimateLine tubing to the H5i, set the most comfortable temperature on the S9 and Climate Control automatically does the rest.

      H5i Water Tub
      The H5i cleanable water tub offers noteable benefits for the sleep professional;
      • Multi patient multi use – (MPMU)
      • Dishwasher cleanable
      ClimateLine Tubing Rainout can occur with high performance humidifiers like the H5i if the added water vapour condenses as it cools through the tubing. Rainout has been shown to adversely affect therapy and impact compliance. (Bacon et al, Chest 2000 Nov; 118(5): 1441-1449). The Climate Control algorithms utilize the heated ClimateLine tubing and a temperature sensor near the mask to manage rainout effectively.

      Technical Specifications
      Materials H5i Cleanable water tub:
      Injection molded plastic,silicone seal, stainless steel Docking station:
      Flame retardant engineering thermoplastic, aluminium
      WATER CAPACITY 380ml
      Single Patient Multi use Yes
      Multi Patient Multi use Yes
      Cleaning Methods Dishwasher; High level
      thermal or chemical
      disinfection
      Number of parts:
      H5i cleanable water tub 5
      Use distilled water? Optional
      Humidification Duration At least 8 hrs (tested to 14hrs at 10cmH2O, 35L/min)